Glossary |
||
|
Description |
Unit |
Summary |
|
A General Works |
|
|
|
Internal Floor Area |
item |
The internal floor area of a building including any upper or lower floors. |
|
1 Site Preparation |
|
|
|
a) Protect Existing Tree |
item |
Any fence protection etc. |
|
b) Remove Shrubs / Plants etc |
item |
As described. |
|
c) Remove Existing Structures |
m2 |
Based on single storey measured by the floor area including loading into skip 20 meters away. |
|
d) Demolish Dwarf 100mm Walls |
m2 |
As described including loading into skip 20 meters away. Multiply by 2 for 200mm wall etc. |
|
e) Lift Existing Paving |
m2 |
As described including loading into skip 20 meters away. |
|
f) Break Up & Remove Concrete Slab |
m2 |
As described including loading into skip 20 meters away. |
|
g) Break Up & Remove Concrete (m3 rate) |
m3 |
Includes wheel and load all into skip 20 meters away, "Note m3 rate". |
|
|
|
|
|
2 Alterations / Demolition |
|
|
|
a) Strip Out Fittings |
item |
Removal of any items prior to works being able to commence. |
|
b) Electrical Disconnection To Area |
item |
To make working area safe. |
|
c) Plumbing Disconnection To Area |
item |
To make working area safe. |
|
d) Scaffolding / Props etc |
item |
Safe working items. |
|
e) Strip Out Single Internal Door / Lining / Architrave |
per |
Single doorway as described including loading into skip 20 meters away. |
|
f) Strip Out Skirting Boards |
Lm |
As described including loading into skip 20 meters away. |
|
g) Remove Timber Stud Walling & Plasterboard |
m2 |
As described including Plasterboard from both sides & loading into skip 20 meters away. |
|
h) Remove 100mm Brick / Blockwork Walling |
m2 |
As described including loading into skip 20 meters away. |
|
i) Remove External Windows / Doors / Frames |
m2 |
As described including loading into skip 20 meters away. |
|
j) Remove Roof Tiles & Roof Spar Timbers |
m2 |
As described including loading into skip 20 meters away. |
|
k) Remove Ceiling Spars / Insulation / Plasterboard |
m2 |
As described including loading into skip 20 meters away. |
|
l) Remove Floorboarding / Joists / Plasterboard Ceiling |
m2 |
As described including loading into skip 20 meters away. |
|
m) Remove Cavity Walling & Insulation |
m2 |
Based on outer brickwork and inner blockwork including loading into skip 20 meters away. |
|
n) Remove Concrete Floor Slab (max 150mm) |
m2 |
As described including loading into skip 20 meters away. |
|
o) Remove Brickwork / Blockwork Foundation & Concrete |
Lm |
Based on 100mm inner & outer solid blockwork including 100mm concrete cavity fill to a depth of 750mm. Concrete strip foundations of 1 x 0.7 x 0.225 all including loading into skip 20 meters away. |
|
p) Make Good To Any Remaining Structures |
item |
As described. |
|
q) Internal Timber Safety Screen (faced with plywood) |
m2 |
Safety screen to enclose working area. |
|
|
|
|
|
3 Foundations |
|
|
|
a) Reduce Dig Site Area (200mm deep) |
m2 |
Original site area assumed to be 150mm lower than the existing finished floor level reduce area by 200mm equates to 350mm below floor level. |
|
b) Set Out Building |
item |
As described. |
|
c) Excavate Foundation Trenches (700mm wide x 900mm deep) |
Lm |
Hand excavate foundation trench 1m long by 700mm wide by 900mm deep from original ground level including wheel and load spoil into skip 20 meters away (retaining approx 30% for back fill). |
|
d) Concrete Foundation Trenches (700mm wide x 225mm deep) |
Lm |
Includes wheel to area 20 meters away, spred and level. |
|
e) Build Cavity Foundation (using standard concrete blocks) |
Lm |
Build up 675mm (3 courses) high blockwork to both inner and outer leafs with a further two courses of common brick topping the inner leaf. |
|
f) Build Cavity Foundation (using trench blocks) |
Lm |
Build up 675mm (3 courses) high blockwork with a further two courses of common bricks to the inner side. |
|
g) Build 225mm Foundation (using standard concrete blocks) |
Lm |
Build up 675mm (3 courses) high blockwork to both inner and outer leafs with a further two courses of common brick topping to both leafs. |
|
h) Build 100mm Foundation (using standard concrete blocks) |
Lm |
Build up 675mm (3 courses) high blockwork with a further two courses of common brickwork topping. |
|
i) A142 Reinforcement (3.6m x 2m sheets) |
m2 |
As described.(include for lapping) |
|
j) Cutting Reinforcement |
item |
As described. |
|
k) Under Slab Services |
item |
As described. |
|
l) Concrete Lintels - P.C.C 100 x 75 x 600 (Over drains/services) |
each |
As described. |
|
Additions |
|
|
|
m) Reduce Dig Site Area (m3 rate) |
m3 |
Includes wheel and load into skip 20 meters away. "Note m3 rate" |
|
n) Standard Excavation Not Exceeding 900mm Deep (m3 rate) |
m3 |
Includes wheel and load into skip 20 meters away, retaining approx 30% for back fill. "Note m3 rate" |
|
o) Excavation Below Standard 900mm Dig (m3 rate) |
m3 |
Includes wheel and load all into skip 20 meters away. "Note m3 rate" |
|
p) Concrete To Foundation Trenches (m3 rate) |
m3 |
Includes wheel to area 20 meters away, spred and level. "Note m3 rate" |
|
q) 100mm 7N Foundation Blockwork (m2 rate) |
m2 |
As described. "Note m2 rate" |
|
r) 300mm Trench Blocks (m2 rate) |
m2 |
As described. "Note m2 rate" |
|
s) 100mm Foundation Common Brickwork (m2 rate) |
m2 |
As described. "Note m2 rate" |
|
t) Tie Wires - 6no per m2 (m2 rate) |
m2 |
As described. "Note m2 rate" |
|
|
|
|
|
4 Floor Slab |
|
|
|
a) Concrete Cavity Fill |
Lm |
Includes wheel to area 20 meters away, spred and level. |
|
b) Back Fill Foundation Trenches |
Lm |
Back fill exposed trenches with retained spoil. |
|
c) Hardcore To Sub-Base (150mm deep) |
m2 |
Includes load and wheel to area 20 meters away. Spread, level and compact into single layer. |
|
d) Sand Blinding (50mm) |
m2 |
Includes load and wheel to area 20 meters away. Spread and level. |
|
e) D.P.M - Heavy Duty Membrane |
m2 |
As described including fitting. |
|
f) 50mm TF 70 Floor Insulation |
m2 |
As described including fitting. |
|
g) 75mm TF 70 Floor Insulation |
m2 |
As described including fitting. |
|
h) 100mm TF 70 Floor Insulation |
m2 |
As described including fitting. |
|
i) Perimeter Upstand Insulation (25mm x 200mm strips) |
m2 |
As described including fitting. |
|
j) Concrete Floor Slab (120mm thick) |
m2 |
Includes wheel to area 20 meters away, spred and level. |
|
k) A142 Reinforcement (3.6m x 2m sheets) |
m2 |
As described.(include for lapping) |
|
l) Cutting Reinforcement |
item |
As described. |
|
Additions |
|
|
|
m) Concrete Cavity Fill (m3 rate) |
m3 |
Includes wheel to area 20 meters away, spred and level. "Note m3 rate" |
|
n) Back Fill Foundation Trenches (m3 rate) |
m3 |
Back fill exposed trenches with retained spoil. "Note m3 rate" |
|
o) Hardcore To Sub-Base (m3 rate) |
m3 |
Includes load and wheel to area 20 meters away. Spread, level and compact into 150mm layers. "Note m3 rate" |
|
p) Sand Blinding (m3 rate) |
m3 |
Includes load and wheel to area 20 meters away. Spread and level. "Note m3 rate" |
|
q) Concrete Floor Slab (m3 rate) |
m3 |
Includes wheel to area 20 meters away, spred and level. "Note m3 rate" |
|
|
|
|
|
5 Drainage |
|
|
|
a) Excavate/Pipe/Bend/Bedding/ Back Fill.(average 600mm deep) |
Lm |
Excavate trench 1metre long by 500mm wide by 600mm deep including wheel and load spoil into skip 20 meters away (retaining 70% for back fill) lay pipe including allowance for bend or coupler, 50mm gravel bedding/topping & surround including back fill of retained spoil. |
|
b) Inspection Chamber - 460mm dia PVCu (600mm deep) |
each |
Installing base / cover / 2 risers & seals. |
|
c) Gully's |
each |
Including allowance for bend / coupler and installing. |
|
d) Soak-a-Ways (1 m³) |
each |
Excavate soak-a-way 1 meter cube including wheel and load spoil into skip 20 meters away (retaining 15% for back fill) fill with clean stone, top off with DPM and cover with 150mm top soil. |
|
e) Connect To Existing Man-Hole |
each |
Including breaking into existing man-hole and making good after. |
|
f) Concrete Cover Protection |
Lm |
Includes wheel to area 20 meters away, spred and level 100mm deep. |
|
g) Divert Existing Drainage |
item |
As described. |
|
h) Reinstate Area After |
each |
As described. |
|
|
|
|
|
6 Super Structure |
|
|
|
a) Face work up to D.P.C |
Lm |
Including loading and laying 3no course below D.P.C (65mm bricks). |
|
b) D.P.C Horizontal |
Lm |
Including loading and laying as described. |
|
c) ThermaClose "Vertical Window & Door Reviles" |
Lm |
Including loading and fitting as described. |
|
d) D.P.C Cavity Trays |
Lm |
Including loading / laying and installing weep vents as described. |
|
e) Tie To Existing Wall |
Lm |
Including toothing existing outer skin and fitting universal wall starters to the inner skin. |
|
f) Cavity Walling (Brickwork / Blockwork) |
m2 |
Including loading and laying outer 65mm pointed brickwork, forming cavity, tie-wires and inner blockwork. |
|
g) Cavity Walling (Block / Block) ready for render |
m2 |
Including loading and laying outer blockwork, forming cavity, tie-wires and inner blockwork. |
|
h) Cavity Wall Insulation (100mm Iso Wool) |
m2 |
Including loading and fitting as described. "see retaining clips below if required" |
|
i) Cavity Wall Insulation (75mm Iso Wool) |
m2 |
Including loading and fitting as described. "see retaining clips below if required" |
|
j) Cavity Wall Insulation (50mm Quinntherm board) |
m2 |
Including loading and fitting as described. "see retaining clips below if required" |
|
k) Cavity Wall Insulation "Tie-Wire Retaining Clips" |
m2 |
As described. |
|
l) 4" Single Brickwork (Facework) |
m2 |
Including loading and laying 65mm pointed brickwork. |
|
m) 9" Brickwork (Faced Both Sides) |
m2 |
Including loading and laying two skins of 65mm pointed brickwork. |
|
n) 4" Single Blockwork |
m2 |
Including loading and laying standard blockwork. |
|
o) 9" Blockwork (2no 4" skins) |
m2 |
Including loading and laying two skins of standard blockwork. |
|
p) 9" Brickwork / Blockwork |
m2 |
Including loading and laying 65mm pointed brickwork and a skin of standard blockwork. |
|
|
|
|
|
7 Lintels / Steel Beams |
|
|
|
a) External (100mm Cavity) Lintel with Arch-former Above |
Lm |
As described "labour included within brick/blockwork rate". |
|
b) External (100mm Cavity) Lintels |
Lm |
As described "labour included within brick/blockwork rate". |
|
c) External Arch Formers |
Lm |
As described "labour included within brick/blockwork rate". |
|
d) Internal (100mm)Box Lintels (100 type) Load Bearing |
Lm |
As described "labour included within brick/blockwork rate". use as a rate for internal steel beams. |
|
e) Internal (100mm) Lintels (none load bearing) |
Lm |
As described "labour included within brick/blockwork rate". |
|
f) Garages - 9" Lintels (Box 200 type) |
Lm |
As described "labour included within brick/blockwork rate". |
|
g) Garages - 4" Lintel (L10) |
Lm |
As described "labour included within brick/blockwork rate". |
|
h) Cranage |
item |
May be required for lifting large beams into place. |
|
|
|
|
|
8 Timber Floor Joists |
|
|
|
a) Floor Joists (225x50xC16) |
Lm |
Including fitting and leveling. |
|
a1) Floor Joists (225x75xC16) |
Lm |
Including fitting and leveling. |
|
b) Notch into web of steel |
each |
As described. |
|
c) Joist Hangers (ADJ type) |
each |
As described. |
|
c1) Joist Hangers (Built In type or cut out pockets) |
each |
Including cutting out brick joint and fitting hanger, alternatively cutting pocket into brickwork. |
|
d) Solid Strutting (200x50xC16) |
Lm |
As described. |
|
e) Restraint Straps (Galv Strap Bent Once 1500mm Long) |
each |
As described. "noggins within joinery 1st fix" |
|
f) Nuts/Bolts/Washers (say 180mm M12 Cup Square) |
each |
As described. |
|
g) Battens (temporary strutting) |
bundle |
As described. |
|
i) Fixings (nails / screws etc) |
rate |
As described. |
|
|
|
|
|
9 Roof Carcasing |
|
|
|
a) Strip Back Main Roof For Tie In |
item |
Including stripping existing tiles / underlay and exposing working area. |
|
b) Tie to existing Roof |
item |
Forming new tie in and valleys. |
|
b1) Layboard & Valley noggins for the above(say 200x25&50x50) |
Lm |
As above |
|
c) Wallplate (say 75x100xC16) |
Lm |
Including cutting and jointing. |
|
d) Wallplate Straps (Galv Strap Bent Once 1200mm Long) |
each |
For the above. |
|
e) Ridge (say 50x200xC16) |
Lm |
As described. |
|
e1) Poleplate (lean to ridge screwed to existing wall) |
Lm |
As described. |
|
f) Hips (say 75x225xC16) |
Lm |
As described. |
|
g) Valley Rafters (say 75x225xC16)see below for noggin & lay board |
Lm |
As described. |
|
h) Perlins (say 75x225xC16) |
Lm |
As described. |
|
i) Rafters (100x50xC16) |
Lm |
As described. |
|
i1) Rafters (125x50xC16) |
Lm |
As described. |
|
i2) Rafters (150x50xC16) |
Lm |
As described. |
|
i3) Rafters (175x50xC16) |
Lm |
As described. |
|
j) Rafter / Ceiling binder & hanger (say 100x50xC16) |
Lm |
As described "used as a horizontal binder and a vertical hanger for strengthening purposes". |
|
k) Ceiling Spars (100x50XC16) |
Lm |
As described. |
|
k1) Ceiling Spar Support (50x50 screwed to wall) |
Lm |
As described "fixed to the existing wall to support new ceiling spars". |
|
l) Ceiling Spars (150x50xC16) |
Lm |
As described. |
|
l1) Ceiling Spar Support (75x50 screwed to wall) |
Lm |
As described "fixed to the existing wall to support new ceiling spars". |
|
m) Ceiling Hangers (say 100x50xC16) |
Lm |
As described. |
|
n) Truss Kit (Including Clips) |
item |
As described "supplied by specialist supplier". |
|
o) Standard Trusses (Measured Wallplate To Wallplate) |
Lm |
As described "labour only to fit specialist supplied kit". |
|
p) Attic Trusses (Measured Wallplate To Wallplate) |
Lm |
As described "labour only to fit specialist supplied kit". |
|
q) Valley Set (diminishing trusses) |
set |
As described "labour only to fit specialist supplied kit". |
|
r) Truss Clips (2no per truss) |
each |
As described "labour only to fit specialist supplied kit". |
|
s) Bracing (say 4"x1") |
Lm |
As described. |
|
t) Cranage |
item |
As described "To lift roof trusses into place". |
|
u) Fascia / Soffit / Soffit Vent / Tilt / Eaves Vent |
Lm |
As described "including 50 x 50 fixed to wall for soffit board support / fixing". |
|
v) Gable Ladder & Barge |
Lm |
As described. |
|
w) Box Ends (fascia returns & fascia to barge ends) |
each |
As described. |
|
x) Valley Boards & Noggin |
Lm |
As described. |
|
y) Box Gutter |
each |
As described. |
|
z) Chimney Back |
each |
As described. |
|
aa) Restraint Straps(Gables & Ceiling)Galv Strap Bent Once 1500mm Long |
each |
As described. "noggins within joinery 1st fix". |
|
bb) Nuts/Bolts/Washers (say 180mm M12 Cup Square) |
each |
As described. |
|
cc) Roof Light / Window (including flashings) |
m2 |
As described. |
|
dd) Fixings (nails /screws etc) |
rate |
As described. |
|
|
|
|
|
10 Remedial / Alterations |
|
|
|
a) Cut Out 100mm Brickwork (including prop / pin / lintel) |
m2 |
As described "including wheel and load rubble into skip 20 meters away". |
|
b) Cut Out 100mm Blockwork (including prop / pin / lintel) |
m2 |
As described "including wheel and load rubble into skip 20 meters away". |
|
c) Cut Out Cavity Walling (including prop / pin / lintel) |
m2 |
As described "including wheel and load rubble into skip 20 meters away". |
|
d) Cut Out & Replace Single Brick |
each |
As described "including wheel and load rubble into skip 20 meters away". |
|
e) Cut Out & Rebuild Small Brickwork Areas (include tooth & bond) |
m2 |
As described "including wheel and load rubble into skip 20 meters away". |
|
f) Cut Out & Rebuild Brick Wall Sections (include tooth & bond) |
m2 |
As described "including wheel and load rubble into skip 20 meters away". |
|
g) Pointing |
m2 |
As described "including raking out". |
|
h) Pointing (Isolated areas not exceeding 1 m²) |
m2 |
As described "including raking out". |
|
i) Temporary internal screen (faced with 1200g visqueen) |
m2 |
As described "including timber uprights at 600¢, base / head timbers and 1no mid span noggin". |
|
|
|
|
|
11 External Doors |
|
|
|
11a) Front Single Door with Mobility Threshold Frame |
|
|
|
a) Door Frame (single mobility) |
each |
As described "including joiner fitting". |
|
b) Doors (joiner swing door) |
each |
As described "including joiner fitting". |
|
c) 4" Butt Hinges (3no) |
3no |
As described "joiner fitting included in door price above". |
|
d) Sach Lock (5 lever mortise lock) |
each |
As described "including joiner fitting". |
|
e) Handles (lever handles) |
set |
As described "including joiner fitting". |
|
f) Letter Plate |
each |
As described "including joiner fitting". |
|
g) Letter Plate Rear Tidy |
each |
As described "including joiner fitting". |
|
h) Chub Security Bolts (2no) |
2no |
As described "including joiner fitting". |
|
i) Chub Security Bolts (Keys)(2no) |
2no |
As described. |
|
j) Glass |
item |
As described. |
|
|
|
|
|
11b) Rear Timber Single Door With Weather Stripped Frame |
|
|
|
a) Door Frame Weather Stripped (single rear door) |
each |
As described "including joiner fitting". |
|
b) Doors (joiner swing door) |
each |
As described "including joiner fitting". |
|
c) 4" Butt Hinges (3no) |
3no |
As described "joiner fitting included in door price above". |
|
d) Sach Lock (5 lever mortise lock) |
each |
As described "including joiner fitting". |
|
e) Handles (lever handles) |
set |
As described "including joiner fitting". |
|
f) Macclesfield Cill (single) |
each |
As described "including joiner fitting". |
|
g) Chub Security Bolts (2no) |
2no |
As described "including joiner fitting". |
|
h) Chub Security Bolts (Keys)(2no) |
2no |
As described. |
|
i) Glass |
item |
As described. |
|
|
|
|
|
11c) Double Timber Door Sets |
|
|
|
a) Door Frame (double - suit pair of doors) |
each |
As described "including joiner fitting". |
|
b) Doors (joiner swing doors) |
pair |
As described "including joiner fitting". |
|
c) 4" Butt Hinges (6no) |
6no |
As described "joiner fitting included in door price above". |
|
d) Rebate Doors |
set |
As described. |
|
e) Sach Lock (5 lever mortise lock) |
each |
As described "including joiner fitting". |
|
f) Rebated Components (double doors) |
each |
As described "including joiner fitting". |
|
g) Handles (lever handles)(2no pairs) |
2 pair |
As described "including joiner fitting". |
|
h) Macclesfield Cill (double) |
each |
As described "including joiner fitting". |
|
i) Chub Security Bolts (4no) |
2no |
As described "including joiner fitting". |
|
j) Chub Security Bolts (Keys)(4no) |
4no |
As described. |
|
k) Glass |
4no |
As described. |
|
|
|
|
|
11d) External PVCu Doors / Frame |
|
|
|
a) Single Door Set |
m2 |
As described "including joiner fitting". |
|
b) Opening French Doors |
m2 |
As described "including joiner fitting". |
|
c) Sliding Patio Doors |
m2 |
As described "including joiner fitting". |
|
|
|
|
|
12 External Windows |
|
|
|
a) Softwood "Casement Window" (factory glazed - clear) |
m2 |
As described "including joiner fitting". |
|
b) Softwood "Casement Window" (frame only) |
m2 |
As described "including joiner fitting". |
|
c) Glazing |
m2 |
As described "including joiner fitting". |
|
d) PVCu "Casement Window" (factory glazed - clear) |
m2 |
As described "including joiner fitting". |
|
|
|
|
|
13 External Frame Sealant |
|
|
|
a) Seal Frames (both sides including head & base) |
Lm |
As described. |
|
|
|
|
|
14 Joinery 1st Fix |
|
|
|
a) Chipboard Flooring (22mm V313 - T&G) |
m2 |
As described "including joiner fitting". |
|
a1) T&G Floor Boarding (softwood 150x25) |
m2 |
As described "including joiner fitting". |
|
b) Stairs |
rate |
As described "including joiner fitting" assess on site. |
|
c) Noggin |
Lm |
As described "including joiner fitting". |
|
d) Studding (50 x 75 scant) |
Lm |
As described "including joiner fitting". |
|
e) Windowboards (25 x 225 pine) |
Lm |
As described "including joiner fitting". |
|
f) 110mm casings (full set fixed to timber stud - 5.2 Lm per set) |
set |
As described "including joiner fitting". |
|
g) 110mm casing leg (3no req per double door set - 2.1 Lm per leg) |
leg |
As described "including joiner fitting" note 3no required for a double door frame. |
|
h) 150mm casings (full set fixed to blockwork - 5.2 Lm per set) |
set |
As described "including joiner fitting". |
|
i) 150mm casing leg (3no req per double door set - 2.1 Lm per leg) |
leg |
As described "including joiner fitting" note 3no required for a double door frame. |
|
j) Loft Hatch (750mm²) |
each |
As described "including joiner fitting". |
|
k) Kingspan Insulation (100mm to sloping ceilings) |
m2 |
As described "including joiner fitting". |
|
l) Kingspan Insulation (75mm to sloping ceilings) |
m2 |
As described "including joiner fitting". |
|
m) Pre-Plaster Boxings (steel / S.V.P etc) |
item |
As described. |
|
n) Alterations To Existing Building |
item |
As described. |
|
p) Fixings (nails /screws etc) |
rate |
As described. |
|
|
|
|
|
15 Joinery 2nd Fix |
|
|
|
a) Architrave (single door both sides) |
set |
As described "including joiner fitting" note includes both sides. |
|
a1) Architrave (double doors both sides) |
set |
As described "including joiner fitting" note includes both sides. |
|
b) Skirting Board (125mm) |
Lm |
As described "including joiner fitting". |
|
b1) Skirting Board (150mm) |
Lm |
As described "including joiner fitting". |
|
b2) Skirting Board (175mm) |
Lm |
As described "including joiner fitting". |
|
c) Alterations To Existing Building |
item |
As described. |
|
d) Fixings (nails /screws etc) |
rate |
As described. |
|
|
|
|
|
16 Internal Doors |
|
|
|
16a) Single Standard Door |
|
|
|
a) Door (joiner swing door) |
each |
As described "including joiner fitting". |
|
b) 3" Loose Pin Hinges |
3no |
As described "joiner fitting included in door price above". |
|
c) 2.5" Mortise Latch |
each |
As described "including joiner fitting". |
|
d) Handle Set |
set |
As described "including joiner fitting". |
|
|
|
|
|
16b) Bathroom Door |
|
|
|
a) Door (joiner swing door) |
each |
As described "including joiner fitting". |
|
b) 3" Loose Pin Hinges |
3no |
As described "joiner fitting included in door price above". |
|
c) Bathroom Lock |
each |
As described "including joiner fitting". |
|
d) Privacy Handle Set |
set |
As described "including joiner fitting". |
|
|
|
|
|
16c) Double Doors |
|
|
|
a) Doors (joiner swing doors) |
2no |
As described "including joiner fitting". |
|
b) 3" Loose Pin Hinges |
6no |
As described "joiner fitting included in door price above". |
|
c) 2.5" Mortise Latch |
each |
As described "including joiner fitting". |
|
d) Rebated Component Set |
each |
As described "including joiner fitting". |
|
e) Handles (2 sets) |
2 sets |
As described "including joiner fitting". |
|
e) Chub Bolts |
2no |
As described "including joiner fitting". |
|
f) Chub Bolt Knobs or Keys |
2no |
As described. |
|
|
|
|
|
17 Loft Insulation |
|
|
|
a) 250mm Insulation (one 150mm layer & one 100mm layer) |
m2 |
As described. |
|
|
|
|
|
18 Final Fix |
|
|
|
a) Boxings |
Lm |
As described "including joiner fitting". |
|
b) Sealant (baths / showers / kitchens) |
Lm |
As described "including joiner fitting". |
|
c) Fixing Shower Screens/Panels etc |
item |
As described. |
|
d) Alterations To Existing Building |
item |
As described. |
|
f) Fixings (nails /screws etc) |
rate |
As described. |
|
|
|
|
|
Description |
Unit |
Summary |
|
B Subcontract |
|
|
|
1 External Scaffolding |
|
|
|
a) Single Storey - 1no lifts Total |
Lm |
As described. |
|
b) Double Storey - 3no lifts Total (2 lifts brickwork - 1 lift roof) |
Lm |
As described. |
|
c) Table Lifts for Gables |
each |
As described. |
|
|
|
|
|
2 Roofing (scaffolding assumed to be supplied by main contractor) |
|
|
|
(Plain Tiles - 100mm gauge) |
|
|
|
a) Underlay & Batten (25x38 Tanalized) |
m2 |
As described. |
|
b) Tiling |
m2 |
As described. |
|
c) Eaves Tiles & Felt |
Lm |
As described. |
|
d) Verge/undercloak/pointing/til&half |
Lm |
As described "note tile & half fitted in alternative rows". |
|
e) Top Tiles (pole-plate level - single row / one side) |
Lm |
As described "note rate for single side, double up for return ridge". |
|
(Modern Tiles - 75mm head lap) |
|
|
|
f) Underlay & Batten (25x38 Tanalized) |
m2 |
As described. |
|
g) Tiling |
m2 |
As described. |
|
h) Eaves Felt |
Lm |
As described. |
|
i) Verge/undercloak/pointing. |
Lm |
As described. |
|
j) Marley Modern (verge clip) |
each |
As described. |
|
k) Marley Modern (tile clip & nails) |
each |
As described. |
|
(General Roofing Items) |
|
|
|
l) Ridge (Capped Angular) |
Lm |
As described. |
|
m) Valleys GRP (large tiles only i.e. Moderns) |
Lm |
As described. |
|
n) Hip Tiles (Capped Angular) |
Lm |
As described. |
|
o) Hip Irons - 4mm |
each |
As described. |
|
p) General Cutting |
Lm |
As described. |
|
|
|
|
|
3 Lead Work (scaffolding assumed to be supplied by main contractor) |
|
|
|
a) Valleys (15" or 380mm Lead) small plain tiles & slate |
Lm |
As described "note pointing covered in builders associated work below" . |
|
b) Plain Tile Soakers (6" or 150mm Lead cut to 10" x 6") |
Lm |
As described. |
|
c) Plain Tile Cover Flashings (9" or 225mm Lead) |
Lm |
As described "note pointing covered in builders associated work below". |
|
d) Modern Tile Cover Flashings (12" or 300mm Lead) |
Lm |
As described "note pointing covered in builders associated work below". |
|
e) Stepped Flashing (9" or 225mm Lead) |
Lm |
As described "note pointing covered in builders associated work below". |
|
|
|
|
|
4 Rainwater Guttering & Down Pipes |
|
|
|
(Guttering)scaffolding assumed to be supplied by main contractor |
|
|
|
a) 112.5mm Half Round UPVc (including brackets @ 900 ¢) |
Lm |
As described. |
|
b) External Stop Ends |
each |
As described. |
|
c) 90° Angle |
each |
As described. |
|
d) 135° Angle |
each |
As described. |
|
e) Running Outlet |
each |
As described. |
|
f) Union Bracket |
each |
As described. |
|
(Down Pipes) |
|
|
|
a) Round 68mm dia PVCu (including brackets @ 1200 ¢) |
Lm |
As described. |
|
b) Top Swan Neck (2no 112.5° offset bends) |
set |
As described. |
|
c) Pipe Connector |
each |
As described. |
|
d) 112.5° Branch |
each |
As described. |
|
e) Shoe |
each |
As described. |
|
|
|
|
|
5 Plastering |
|
|
|
(Ceilings) |
|
|
|
a) Standard 12.5mm Boarded Ceiling / Skimming |
m2 |
As described. |
|
b) 12.5mm Plasterboard (Vapor Check Foil Backed"duplex") |
m2 |
As described. |
|
c) 12.5mm Plasterboard "Fireshield" |
m2 |
As described. |
|
d) 37.5mm Plasterboard (Insulated-Kooltherm K17) |
m2 |
As described. |
|
(Timber Stud Partitions Walls) |
|
|
|
a) Standard 12.5mm Plasterboard / Skimming (single side) |
m2 |
As described. |
|
(Sound Insulation - Wall & Ceilings) |
|
|
|
a) 100mm Mineral Wool Sound Insulation (Ceilings) |
m2 |
As described. |
|
b) 50mm Multi Purpose Acoustic Mat (Partition Walls) |
m2 |
As described. |
|
(Dry Lining Walls - dot & dab) |
|
|
|
a) Standard 12.5mm Plasterboard |
m2 |
As described. |
|
(Float & Skim Walls) |
|
|
|
a) Standard 11mm Base & 2mm Top Coat |
m2 |
As described. |
|
(Gyproc Cove) |
|
|
|
a) Plain 127mm |
m2 |
As described. |
|
(Plain Face Render) |
|
|
|
a) Standard 6mm base & 6mm Top Coat 4-1 Mix |
m2 |
As described "scaffolding assumed to be supplied by main contractor". |
|
(Beading) |
|
|
|
a) Thincoat Beads |
Lm |
As described. |
|
b) Angle Beads |
Lm |
As described. |
|
c) Bellcast Beads |
Lm |
As described. |
|
d) Stop Beads |
Lm |
As described. |
|
Addition |
|
|
|
a) Plaster Patching To Existing |
item |
As described. |
|
|
|
|
|
6 Floor Screed |
|
|
|
a) 65mm Screed (1:5 mix ratio) |
m2 |
As described. |
|
b) 75mm Screed (1:5 mix ratio) |
m2 |
As described. |
|
c) Insulation (see floor slab above) |
|
As described. |
|
a) |
m2 |
As described. |
|
|
|
|
|
7 Heating - PC Sum |
rate |
As described." note ²F rate" |
|
|
|
|
|
8 Plumbing - PC Sum |
rate |
As described." note ²F rate" |
|
|
|
|
|
9 Electrical - PC Sum |
rate |
As described." note ²F rate" |
|
|
|
|
|
10 Supply & Fix Wall/Floor Tiles - PC Sum or Not Included |
rate |
As described. |
|
|
|
|
|
11 Supply & Fit Kitchen Units - PC Sum or Not Included |
rate |
As described. |
|
|
|
|
|
12 Supply Of Sanitary Ware - PC Sum or Not Included |
rate |
As described. |
|
|
|
|
|
13 Internal / External Decoration PC Sum or Not Included |
rate |
As described. |
|
|
|
|
|
14 Addition |
rate |
Any additional trade or trades not included above. |
|
|
|
|
|
15 Builders Associated Work |
rate |
Any additional work associated with Sub-Contractors i.e. lifting floor boards / chasing in / grooving / pointing / making good after etc. |
|
|
|
|
|
Description |
Unit |
Summary |
|
C General Terminology |
|
|
|
1) Preliminaries |
item |
A cost inserted by the Main Contractor to cover general site running costs not itemized i.e. Site Set Up / Delivery Of Materials / Supervision / Mobile Phones / Vehicle / Welfare / Storage / Skips For General Rubbish / Small Tools/ Final Clean etc."Adjust allowance to suit each individual contract.". |
|
2) Contingency |
item |
A cost inserted by the Main Contractor to cover any unforeseen event / problem / expense that might arise unexpectedly."Adjust allowance to suit each individual contract." |
|
3) Overheads & Profit |
item |
Main Contractors general business running costs & excess of income over expenditure."Adjust allowance to suit each individual contract." |
|
4) PC Sum / Provisional Sums |
item |
A sum of money inserted into a contract to cover the estimated cost of a specific item of work. This money may or may not be spent under the contract. |
|
5) Additions |
item |
Any additional materials / tool-plant hire / skips / work-works / trade-trades or any other items required that are not included within this schedule. "to be assess and quantified." |
|
6) m2 or M2 |
item |
Square Meter. |
|
7) Lm |
item |
Linear Meter. (straight line) |
|
8) m3 or M3 |
item |
Meter Cube. |
|
9) m or M |
item |
Meter. |
|
10) " |
item |
inch |
|
11) ²F |
item |
Square Foot. (imperial measure) |
|
12) no |
item |
Number. |
|
13) hr |
item |
Hour. |
|
14) hrs |
item |
Hours. |
|
15) kg |
item |
Kilogram. |
|
16) £ |
item |
Pounds Sterling.(British currency) |
|
17) yrd |
item |
Yard. (imperial measure) |
|
|
|
|
|
Description |
Unit |
Summary |
|
D General Notes |
|
|
|
1) Skips |
note |
Less skips may be required than indicated if finer none-bulking material loaded. |